[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 12, Issue 4 (witner 2014) ::
jjums 2014, 12(4): 31-36 Back to browse issues page
Comparison of Test Results of Complete Blood Cell Count Obtained by Means of Routine Venipuncture Procedure and Peripheral Intravenous Infusion Line after the Administration of Fluids
Mohammadreza Yazdankhahfard , Mahboobeh Taghizadeganzadh , Mohammadreza Farzaneh , Kamran Mirzaei
1- Lecturer, Faculty of Nursing and Midwifery, Bushehr University of Medical Sciences, Bushehr, Iran. Bushehr University of Medical Sciences
Abstract:   (3209 Views)
Abstract Introduction: A number of factors can affect hematological measurements among which the effect of blood sample collection procedures by nurses in hematology test results is of great importance. Therefore, this study was carried out with the aim of determining and comparing the experimental values of complete blood cell count through taking blood samples from peripheral vein infusion of intravenous fluids and routine blood sampling procedure while receiving continuous IV fluids. Methods: This quasi-experimental intervention study was done on 60 patients hospitalized in the internal medicine ward who were selected for blood sampling. Two samples were taken from each patient through a peripheral intravenous line after throwing the first 5 cc of IV away and collecting the remaining 5 cc and through the routine blood sampling procedure for the case and control group, respectively. Then all the samples were analyzed in terms of the number of white blood cells, red blood cells, platelets, hemoglobin and Hematocrit using SPSS software19, paired t-test and Pearson correlation. Results: The mean values of white blood cells, red blood cells, platelets, hemoglobin and Hematocrit in the case group were 9694 mm3, 4433000 mm3, 240166 mm3, 12.52 gr/dl, 38.90% and 9587 mm3, 4588800 mm3, 244800 mm3, 12.68 gr/dl, 38.96% in the control group, respectively. A significant difference was only observed in hemoglobin values between the case and control groups. Conclusion: In order to measure the amount of white blood cells, red blood cells, platelets and Hematocrit, blood samples taken from peripheral vein infusion can be used after throwing away 5 cc at the beginning of the sampling. Keywords: complete blood cell count, peripheral vein catheter, phlebotomy
Keywords: Keywords: complete blood cell count, peripheral vein catheter, phlebotomy
Full-Text [PDF 382 kb]   (3365 Downloads)    
Type of Study: Applicable |
Received: 2014/08/12 | Accepted: 2014/12/22 | Published: 2015/02/28
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

yazdankhahfard M, taghizadeganzadh M, farzaneh M, mirzaei K. Comparison of Test Results of Complete Blood Cell Count Obtained by Means of Routine Venipuncture Procedure and Peripheral Intravenous Infusion Line after the Administration of Fluids. jjums. 2014; 12 (4) :31-36
URL: http://jmj.jums.ac.ir/article-1-393-en.html
Volume 12, Issue 4 (witner 2014) Back to browse issues page
فصلنامه دانشگاه علوم پزشکی جهرم Journal of Jahrom University of Medical Sciences
Persian site map - English site map - Created in 0.052 seconds with 796 queries by yektaweb 3510